สั่งจองล่วงหน้า

Autoclave HV-Series, Hirayama

SKU : U11-HI-A085-0080

HV-80

Features & Functions Electro-mechanical lid lock system The lid can be opened and closed easily and reliably with the one-touch lever. A pressure seal method is used as a safety measure. Dual interlock mechanism The lid is locked by dually detecting the chamber pressure and chamber temperature during operation. The lock state is maintained even if an operation is manually interrupted. Dual detection system for residual air The residual air which may cause sterilization failure is dually detected to always maintain the appropriate sterilization conditions for loads. The residual air is detected at the process before pressurization (during operation of an air removal timer) and at the process of pressurization air exhaust. Exhaust level can be set digitally Fine exhaust can be performed automatically, and fine exhaust adjustment is possible even in exhaust. Memory function Set contents can be registered for each mode.
฿0
฿0
ราคาสมาชิก
 
฿0
ราคาสมาชิก
฿0

Autoclave

SPECIFICATIONS

Model nameHV-50 IIHV-80 IIHV-110 II
 Classification of MD/LBMD
 Chamber dimensionØ300 x D710 mmØ420 x D615 mmØ420 x D795 mm
 Chamber volume54.2L98.8L123.7L
 Effective capacity50L85L110L
 Temp. settings Strilization temperature105 - 135 °C Variable
 Dissolution temperature60 - 100 °C Variable
 Warming temperature45 - 60 °C Variable
 Lid lock temperatureLIQUID, AGAR, DISSOL modes: 60-95°C variable, SOLID, WASTE modes: 60-97°C variable
 Time settings Strilization timer1-250 min, The remaining time is displayed.
 Dissolution temer1-60 min, The remaining time is displayed.
 Auto-start timer1 min later-1 week later, A start date and time is set
 Air removal time3-9 min variable6-18 min variable
 Mode selectionLIQUID, SOLID, WASTE, AGAR, DISSOL/8 programs
 Exhaust settings3 steps (No exhaust, Fine exhaust, Small amount of exhaust)
 Maximum working pressure0.255MPA
 ThermometerDigital disaply 5.0 - 137.9°C
 Pressure guageDigital display 0-0.3 MPa/Analog display 0-0.4 MPa  
 Safety devices and alarmsSafe pressure valve, Earth leakage breaker with O.C,protection, Low water cut off device, Alarms: Low water heating, Temperature sensor wire disconnection, Over-temperature, Over-cool, Over-pressure, Abnormality in lid, Abnormality in the lock of lid opening/closing lever
 Sterilization timer1 - 250 Min, the remaining time is displayed
 Outside dimention (in mm)W 547 x D 532 x H 1046W 667 x D 652 x H 1,026W 667 x D 652 x H 1,180
 Air removal time3 - 9 min Variable6 - 18 min Variable
 Weight (approx.)60 kg83 kg89 kg
 Chamber materialStainless steel (SUS 304)
 Power soureeAC 110/120/220/230/240, 50/60HzAC 220/230/240, 50/60Hz
 Power consumption2.0kW3.0kW4.0kW
 Power cord connectionRing terminal (A plug is not supplied.)