สั่งจองล่วงหน้า

Humidity Chamber HCP-Series, memmert

SKU : U11-MM-HCP0-0050

HCP50

Humidity chamber HCP Active humidity control creates a controlled environment for accelerated life tests and 85/85 tests.This climate chamber offers the full range of comfort, reliability, and safety. It has active humidity control set from 20 % to 95 % rh and an unsurpassed homogeneity of temperature and humidity over the entire interior. It is suited for environmental testing, environmental simulation, accelerated service life tests, and 85/85 tests according to IEC 60068-2-67 and IEC 60068-2-78.
฿0
฿0
ราคาสมาชิก
 
฿0
ราคาสมาชิก
฿0

Humidity Chamber HCP-Series
รายละเอียดสินค้า

SPECIFICATIONS

Temperature

ModelHCP50HCP105HCP150HCP240
 Working-temperature range+7 above ambient temperature up to +90 °C
 Setting temperature range+18 to +90 °C
 Setting accuracy temperature0.1 °C
 Temperature sensor2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error

Humidity

ModelHCP50HCP105HCP150HCP240 
 Humidity Control Active microprocessor control for humidifying and dehumidifying (20 95 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times. Humidity supply with water (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7; from an external tank) by a self-priming pump; integral bacteria block by generating hot steam, dehumidifying via sterile filter    
 Setting range active humidity control20 to 95 % rh and rh-Off    
 Setting accuracy humidity0.5 % rh    

 

Stainless steel interior

ModelHCP50HCP105HCP150HCP240
 Dimensions (d less 35 mm for fan)400 x 425 x 330 mm560 x 480 x 400 mm560 x 700 x 400 mm600 x 810 x 500 mm
 InteriorW.-St. 1.4301 (ASTM 304)
 Volume56 l107 l156 l 241 l
 Max. number of internals5 610  12
 Max. loading of chamber75 kg 90 kg 120 kg 140 kg
 Max. loading per internal15 kg   

 

Textured stainless steel casing

ModelHCP50HCP105HCP150HCP240
 Dimensions (d +56mm door handle)559 x 795 x 521 mm719 x 850 x 591 mm719 x 1070 x 591 mm719 x 1070 x 591 mm

 

Electrical data

ModelHCP50HCP105HCP150HCP240
 Voltage Electrical load230 V, 50/60 Hz
approx. 1520 W
230 V, 50/60 Hz
approx. 1720 W
230 V, 50/60 Hz
approx. 1800 W
230 V, 50/60 Hz
approx. 1840 W
 Voltage Electrical load115 V, 50/60 Hz
approx. 1520 W
115 V, 50/60 Hz
approx. 1720 W
115 V, 50/60 Hz
approx. 1800 W
115 V, 50/60 Hz
approx. 1840 W

 

Ambient conditions

ModelHCP50HCP105HCP150HCP240
 Ambient temperature10 °C to 30 °C
 Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.
 Humidity rhmax. 70 %, non-condensing
 Altitude of installationmax. 2,000 m above sea level
 Overvoltage categoryII
 Pollution degree